    Title: Analysis of large-volume DNA markers and polymerase chain reaction products by capillary electrophoresis in the presence of electroosmotic flow
    Authors: Tseng, Wei-Lung;Hsieh, Ming-Mu;Wang, Shang-Ji;Huang, Chih-Ching;Lin, Yu-Cheng;Chang,Po-Ling;Chang,Huan-Tsung
    Contributors: 輔英科技大學 應用化學及材料科學系
    Keywords: DNA;poly(ethylene oxide)
    Date: 2001-08-24
    Issue Date: 2010-09-28 16:53:40 (UTC+8)
    Abstract: We have demonstrated on-line concentration and separation of DNA in the presence of electroosmotic flow (EOF) using poly(ethylene oxide) (PEO) solutions. After injecting large-volumes DNA samples, PEO solutions entered a capillary filled with 400 mM Tris–borate (TB) buffers by EOF and acted as sieving matrices. DNA fragments stacked between the sample zone and PEO solutions. Because sample matrixes affected PEO adsorption on the capillary wall, leading to changes in EOF, migration time, concentration, and resolving power varied with the injection length. When injecting ΦX174 RF DNA–HaeIII digest prepared in 5 mM Tris–HCl buffer, pH 7.0, at 250 V/cm, peak height increased linearly as a function of injection volume up to 0.9 μl (injection time 150 s). The sensitivity improvement was 100-fold compare to that injected at 25 V/cm for 10 s (0.006 μl). When injecting 1.54 μl of GeneScan 1000 ROX, the sensitivity improvement was 265-fold. The sensitivity improvement was 40-fold when injecting 0.17 μl DNA sample containing pBR 322/HaeIII, pBR 328/BglI, and pBR 328/HinfI digests prepared in phosphate-buffered saline. This method allows the analysis of polymerase chain reaction (PCR) products amplified after 17 cycles when injecting 0.32 μl (at 30 cm height for 300 s). The total analysis time was shorter (91.6 min) than that (119.6 min) obtained from injecting PCR products after 32 cycles for 10 s.
    Relation: Journal of Chromatography A ,Volume 927, Issues 1-2, Pages 179-190
    Appears in Collections:[應用化學及材料科學系] 期刊論文

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML1056View/Open


    All items in FYIR are protected by copyright, with all rights reserved.


    本網站典藏內容為學術研究目的之提供,請尊重著作權人之權益合理使用,請勿任意重製、轉貼、改作及散佈。

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback