English  |  正體中文  |  简体中文  |  Items with full text/Total items : 6024/14565 (41%)
Visitors : 13701250      Online Users : 273
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://ir.fy.edu.tw:8080/ir/handle/987654321/3254


    Title: Indirect fluorescence of aliphatic carboxylic acids in non-aqueous capillary electrophoresi using merocyanine 540
    Authors: Chiu, Tai-Chia;Huang, Ming-Feng;Huang, Chih-Ching;Hsieh, Ming-Mu;Chang,Huan-Tsung
    Contributors: 輔英科技大學 應用化學及材料科學系
    Keywords: Aliphatic carboxylic acid;Indirect laser-induced fluorescence;Merocyanine 540;Nonaqueous capillary electrophoresis
    Date: 2002-02
    Issue Date: 2010-09-28 16:53:41 (UTC+8)
    Abstract: A method for the analysis of aliphatic carboxylic acids (ACAs) in nonaqueous capillary electrophoresis (NACE) in conjunction with indirect laser-induced fluorescence (ILIF) using merocyanine 540 (MC 540) is described. Performing the analysis in organic solvent is advantageous when using MC 540, because of its greater quantum yield in aprotic solvent. To achieve a high dynamic reserve (DR) and optimize resolution, we have tested a number of aqueous mixtures containing alcohols and acetonitrile (ACN). The optimum buffer for the analysis of C2-C18 ACAs, in terms of sensitivity, resolution, and speed, is an aqueous mixture of 40% ACN, 30% ethanol, and 1 mM Tris at apparent pH 7.4 (adjusted with ascorbic acid). Under this condition, the DR is greater than 1000, thereby the limits of detection for acids are in the range of sub-νM to νM. Linear plots show that the dynamic ranges for the analysis of ACAs are at least two decades in concentration, with regression coefficients all greater than 0.98. The relative standard deviations of the migration times and peak heights for all ACAs are less than 2.0%. Furthermore, this simple and cost-effective method has been applied to the analysis of marine lipid concentrate, with the concentrations of 1.67 ± 0.03 and 4.50 plusmn; 0.05 mM (n = 5) for C14 and C16 acids, respectively, in a tablet of marine lipid concentrate sample.
    Relation: Electrophoresis 23(3),445-449
    Appears in Collections:[應用化學及材料科學系] 期刊論文

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML793View/Open


    All items in FYIR are protected by copyright, with all rights reserved.


    本網站典藏內容為學術研究目的之提供,請尊重著作權人之權益合理使用,請勿任意重製、轉貼、改作及散佈。

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback